Only after checking the waterway and circuit are correct can the machine be turned on. The startup sequence is:
① Connect the incoming power and turn on the key switch. At this time, the machine's ventilation and refrigeration system is powered on, and the ammeter shows a value of about 7A;
② Wait for 5-10 seconds, press the trigger button on the external control panel, and the ammeter will display a value of zero. After 3-5 seconds, the Krypton lamp will light up, and the ammeter will display a value of 7A. (Refer to the laser power supply operation manual);
③ Turn on the power supply of the galvanometer;
④ Open the computer and retrieve the required marking file;
⑤ Adjust the laser power supply to the working current (10-18A) to start marking;
After marking, turn off the power supply of each component in reverse order as follows:
① Adjust the working current of the laser power supply to the minimum (about 7A);
② Turn off the computer;
③ Turn off the power supply of the galvanometer;
④ Press the stop button;
⑤ Turn off the key switch;
⑥ Disconnect the incoming power supply.